TECH SPECS: THE HAMMERSTEIN BALLROOM
- STAGE LEFT
- STAGE RIGHT
- LOWER DIMMER ROOM; HOUSE LEFT
- BASEMENT (35TH ST. SIDE)
- BASEMENT (34TH ST. SIDE; HOUSE RIGHT)
200 amps, 3 phase (camlocks — isolation transformer); house audio uses this
200 amps, 3 phase (camlocks) — additional/guest stage lighting
400 amps, 3 phase (camlocks) — house lighting uses this
(2) 400 amps, 3 phase (camlocks)
(2) 200 amps, 3 phase (camlocks)
(1) 800 amps, 3 phase (bare ends)
200 amps, 3 phase (camlocks)
400 amps, 3 phase (camlocks)
68'W x 24'D x 4'H permanent stage (please note: big black curtain is 4' 6" from upstage wall to create crossover lane)
An additional 56'W x 16'D x 4'H extension can be added. Staging Concepts SC90 decks.
FOH SYSTEM:
L’acoustics K2, 12 boxes per side 6 SB28 subwoofers per side
4 Kara front fills all powered by L’Acoustics LA-8 amplifiers
Avid Profile console with 5 DSP mix engines — Waves 9 installed (but not authorized)
MONITOR SYSTEM:
16x L’Acoustics 115HiQ wedges across 10 mixes
2x sidefills (2 ARC2 and 1 SB28 per side)
Avid Profile console with 4 DSP mix engines — Waves 9 installed (but not authorized)
4x Shure UHF-R wireless mic’s
2x Beta 91
1x Beta 52
1x Senn 602
12x SM57
6x Beta 98
6x Senn 604
8x Audix I5
10x SM58
4x Beta 58
2x Audio Technica 4051
2x KSM32
4x Audio Technica 4033
10x Radial JDI boxes
10x Radial J48 DI boxes
2x Christie Roadster 14K projectors
2x Christie Roadster 20K projectors
2x 7' x 12' screens
1x 11' x 20' screen (can do front or rear projection)
1x 18' x 32' screen
Panasonic 450 switcher
STAGE LIGHTING:
3 truss system
12x Mac Viper profiles
8x Mac Viper DX washes
16x Mac Aura LED wash
8x 26-degree Lekos
6x 4-light Molefay units
5x Atomic 3000 strobes
Grand MA II full-size lighting console
Please contact for more detailed lighting plot and patch sheet.
ROOM LIGHTING:
Trusses left and right in stagehouse each with 12x Source 4 lekos for gobo breakup
Box towers east and west each with 6x Source 4 lekos for gobo breakup
13 line sets
Line sets 1, 2 and 13 are reserved for Hammerstein soft goods.
All line sets can support 1,000 lbs. with the exception of line sets 4 and 12 which can only support 350lbs.
THE HAMMERSTEIN BALLROOM TECH SPECS PDF
TECH SPECS: THE GRAND BALLROOM
200 amps — cam locks needs bolt switch, located up and off stage left
100 amps — cam locks
400 amps — cam locks — only available if house lighting is NOT being used
100 amps — camlocks (ground and neutral reversed) iso transformer for audio
400 amps — cam locks(if not using GB room lighting)
200 amps for motor power in ceiling
Nexo line array sound system
8x GEOS1210 per side (flown)
1x GEOS1230 per side (flown)
3x Alpha S2-PF dual 18" subwoofers per side (ground stacked)
4x Yamaha IF2208 front fills
FOH system powered by Yamaha T3N and T5N amplifiers
Front fills powered by a Yamaha PC650 1N amplifier
Yamaha CL5 console
10x PS15 high power 2-way bi-amped wedges
2x PS15BAS 15" drum subs
SIDE FILL SYSTEM:
2x Alpha EF 3 way side fills
2x Alpha 18" subwoofers
2x Alpha S2-PF dual 18" subwoofers
Powered by Yamaha T3N, T4N, and T5N amplifiers
Yamaha CL 5 console
1x Shure Beta 91
1x Shure Beta 52
1x Sennheiser MD 421
1x AKG C112
1x Shure Beta 98
2x Audiotechnica Pro 35
1x AKG 460
2x AKG 414 B-ULS
6x Shure Beta 58
4x Shure Beta 87
2x Shure Beta 57
8x Shure SM 57
1x Audiotechnica 4051
1x Sony CP-55
1x Beyer 834
2x Beyer 422 short mic’s
5x CountryMan DI boxes
4x Whirlwind IMP DI boxes
THE GRAND BALLROOM TECH SPECS PDF
Jessica Rothstein Berman, CMP
Vice President of Sales
646-293-1077
Dimitra Trakellis
Assistant Director of Sales
646-293-1078
Ali Harvazinski
Account Executive
646-293-1086
311 W 34TH ST (BETWEEN 8th & 9th AVES), NEW YORK, NY 10001 (212) 695-6600
311 W 34TH ST (BETWEEN 8th & 9th AVES), NEW YORK, NY 10001 (212) 695-6600